Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-21266579

RESUMO

ObjectiveTo assess the diagnostic accuracy of three rapid antigen tests (Ag-RDTs) for detecting SARS-CoV-2 infection in the general population. DesignCross-sectional study with follow-up using pseudonymised record linkage. SettingThree Dutch public health service COVID-19 test sites. ParticipantsConsecutively included individuals aged 16 years and older presenting for SARS-CoV-2 testing. Main outcome measuresSensitivity, specificity, positive and negative predictive values of BD-Veritortm System (Becton Dickinson), PanBio (Abbott), and SD-Biosensor (Roche Diagnostics), applying routinely used sampling methods (combined oropharyngeal and nasal [OP-N] or nasopharyngeal [NP] swab), with molecular testing as reference standard. For SD-Biosensor, the diagnostic accuracy with OP-N sampling was also assessed. A viral load cut-off ([≥]5.2 log10 SARS-CoV-2 E-gene copies/mL) served as a proxy of infectiousness. ResultsSARS-CoV-2 prevalence and overall sensitivities with 95% confidence intervals were 188/1441 (13.0%) and 129/188 (68.6% [61.5%-75.2%]) for BD-Veritor, 173/2056 (8.4%) and 119/173 (68.8% [61.3%-75.6%]) for PanBio, and 215/1769 (12.2%) and 160/215 (74.4% [68.0%-80.1%]) for SD-Biosensor with routine sampling, and 164/1689 (9.7%) and 123/164 (75.0% [67.7%-81.4%]) for SD-Biosensor with OP-N sampling. In those symptomatic or asymptomatic at sampling, sensitivities were 72.2%-83.4% and 54.0%-55.9%, respectively. With a viral load cut-off, sensitivities were 125/146 (85.6% [78.9%-90.9%]) for BD-Veritor, 108/121 (89.3% [82.3%-94.2%]) for PanBio, 160/182 (87.9% [82.3%-92.3%]) for SD-Biosensor with routine sampling, and 118/141 (83.7% [76.5%-89.4%]) with OP-N sampling. Specificities were >99%, and positive and negative predictive values >95%, for all tests in most analyses. 61.3% of false negative Ag-RDT participants returned for testing within 14 days (median of 3 days, interquartile range 3) of whom 90.3% tested positive. ConclusionsThe overall sensitivities of the three Ag-RDTs were 68.6%-75.0%, increasing to at least 85.6% after the viral load cut-off was applied. For SD-Biosensor, the diagnostic accuracy with OP-N and NP sampling was comparable. Over 55% of false negative Ag-RDT participants tested positive during follow-up.

2.
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20234104

RESUMO

BackgroundRapid detection of infectious individuals is essential in stopping the further spread of SARS-CoV-2. Although rapid antigen test is not as sensitive as the gold standard RT-PCR, the time to result is decreased by day(s), strengthening the effectiveness of contact tracing. MethodsThe Roche/SD Biosensor lateral flow antigen rapid test was evaluated in a mild symptomatic population at a large drive through testing site. A second nasopharyngeal swab was directly tested with the rapid test on site and results were compared to RT-PCR and virus culture. Date of onset and symptoms were analysed using data from a clinical questionnaire. ResultsWe included 970 persons with complete data. Overall sensitivity and specificity were 84.9% (CI95% 79.1-89.4) and 99.5% (CI95% 98.7-99.8) which translated into a positive predictive value of 97.5% (CI95% 94.0-99.5) under the current regional PCR positivity of 19.2%. Sensitivity for people with high loads of viral RNA (ct <30, 2.17E+05 E gene copy/ml) and who presented within 7 days since symptom onset increased to 95.8% (CI95% 90.5-98.2). Band intensity and time to result correlated strongly with viral load thus strong positive bands could be read before the recommended time. Around 98% of all viable specimen with ct <30 were detected successfully indicating that the large majority of infectious people can be captured with this test. ConclusionAntigen rapid tests can detect mildly symptomatic cases in the early phase of disease thereby identifying the most infectious individuals. Using this assay can have a significant value in the speed and effectiveness of SARS-CoV-2 outbreak management. SummaryO_LIPeople with early onset and high viral load were detected with 98.2% sensitivity. C_LIO_LI97% of individuals in which virus could be cultured were detected by the rapid test. C_LIO_LIThis test is suitable to detect mild symptomatic cases. C_LI

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...